1.
General scope
1-1
The specifications apply to the coreless cylindrical
permanent magnetic micro vibration motor DC model
Z6S00B006F.
2.
Operating conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
3.0V DC
|
|
|
2-2
|
Rated load
|
Counter weight
|
As specified in the outline drawing.
|
|
2-3
|
Rotation
|
C.W. (clockwise)
|
|
|
2-4 |
Motor position
|
All positions
|
|
|
2-5
|
Operating voltage
|
2.0 ~ 3.8V DC
|
|
|
2-6 |
Operating conditions
|
-30 ~ 70°C, ordinary humidity
|
No condensation of moisture.
|
|
2-7
|
Storage conditions
|
-40 ~ 80°C, ordinary humidity
|
No condensation of moisture.
|
3.
Measuring conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Motor shaft horizontal
|
Lock the motor in a test fixture.
|
3-4 All data are based on
the measuring conditions: Temperature, 20°C; Humidity, 65% RH. If any
disagreement occurs, such test conditions are available: Temperature,
5~35°C; Humidity, 45 ~ 85% RH.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified in outline drawing
|
Outline drawing No:
Z6SCAB0061141.
Old number =
Z6S00B006F |
|
4-2
|
Appearance
|
There shall be no evidence of mechanical
damage and shall not have inadequate corrosion, etc.
|
Visual examination: Inspection carried out
on samples.
|
|
4-3
|
Shaft end play
|
0.1 ~ 0.3mm
|
|
|
4-4
|
Mass
|
2.6g approx.
|
Body + Vibration
weight: 2.00+0.52.
|
|
4-5
|
Holding strength of vibration weight
|
49N (5kgf)
|
|
5.
Performance and characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
10,000±2,000rpm
|
At rated voltage and rated load (vibration
weight).
|
|
5-2
|
Rated current
|
70mA
max
|
|
5-3
|
Stall current
|
100mA max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
1.7V
DC max
|
At rated load (vibration weight) any
position of rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between the lead wires and
motor body.
|
|
5-6
|
Terminal resistance
|
35Ω
approx.
(±20%) |
At 20°C.
|
|
5-7
|
Mechanical noise
|
50db (A) max
|
|
|
Measured at rated voltage and rated load
(vibration weight).
Background noise: 28db (A) max. @ 10cm.
Measuring instruments: B & K.
The weight of jig: 700g.

|
6. Reliability Test
|
Items
|
Standard test conditions
|
Condition & Remarks
|
|
6-1
|
Life test
|
 |
After 2 hours exposure in ordinary Motors
shall be approved as specified in item 7-1.
|
|
Position
|
|
Horizontal
|
|
Voltage
|
Rated
|
Rated
|
|
Load
|
|
|
|
Temperature
|
20°C
|
40°C
|
|
Humidity
|
65%
|
90%
|
|
Life (cycles)
|
200,000
|
400,000
|
|
6-2
|
Low temperature exposure test
|
Temperature: -40±2°C
Time: 96hrs
|
After 2 hours exposure in ordinary Motors
shall be approved as specified in item 7-2.
|
|
6-3
|
High temperature exposure test
|
Temperature: 60±2°C
Time: 96hrs
|
|
6-4
|
High humidity exposure test
|
Temperature: 40±2°C
Humidity: 90 ~ 95% RH
Exposure time: 240hrs
Dry time: 4hrs
No condensation of moisture
|
|
6-5
|
Vibration test
|
Displacement: 1.5mm (p-p)
Frequency: 10 ~ 55Hz
Period: 20 Mins log sweep
(10 ~ 55 ~ 10Hz)
Direction: x, y, z
Time: Every 2 hours
|
After the test motors shall be approved as
specified in item 7-2.
|
|
6-6
|
Drop test
|
Set the motor to the approximately 75g
(include the motor) weight of block drop the motor on the concrete
floor.
Height: 1.5 meters
Direction: ±x, ±y, ±z
Times: Twice Each
|
After the test motors shall be approved as
specified in item 7-2.
|
|
6-7
|
Heat stock test
|

Period: 32 cycles
Exposed at ordinary temperature and
ordinary humidity for 24 hours before measurement.
|
After the test motors shall be approved as
specified in item 7-2.
|
7. Post environmental
|
Items
|
Requirements
|
|
7-1
|
Table A
|
1) Rated
speed: Initial data -30% min./ +60%
max.
2) Rated
current: Initial data ±30% max
3) Insulation resistance: 1MΩ min
4) Starting voltage:
1.1V DC max
5) Current waveform: Normal |
|
7-2
|
Table B
|
1) Rated speed:
Initial data -30% min./ +60% max.
2) Rated current:
Initial data ±30% max
3) Starting voltage:
1.1V DC max
|
8.
Matters to be paid attention to when using motor
8-1 Lay the motors
carefully in transportation to avoid any damage to the motor body or its
electric function because of collision.
8-2 Storage
temperature 20°C±10°C.
Do not leave the motors in the environment of high temperature, high
humidity and gas that will cause rust and corrosion. Please don’t store the
motors for over 6 months.
8-3 Do not lock the
motor shaft when the electric power is supplied.
8-4 Do not touch
the weights when motor is rotating.
|