1.     General scope

1-1 The specifications applies to cylindrical permanent-magnetic motors DC model  Z4TL2B1240641.

2.   Operating conditions

Items

Specifications

Condition & Remarks

2-1

Rated voltage

3.0V DC

 

2-2

Rated load

Counter weight

As specified in the outline drawing.

2-3 Rotation C.W/C.C.W  

2-4

Motor position

All positions

 

2-5

Operating voltage

2.2~3.6V DC

 

2-6

Operating conditions

-30 ~ 70°C, ordinary

humidity:  65±20%RH

No condensation of moisture.

2-7

Storage conditions

-40 ~ 80°C, ordinary

humidity:  65±20%RH

No condensation of moisture.

3.   Measuring conditions

Items

Specifications

Condition & Remarks

3-1

Temperature

20±2°C

 

3-2

Humidity

(63% ~ 67%) RH

 

3-3

Motor position

Shaft horizontal

Lock the motor in a test fixture.

3-4 The measurement at 20°C & 65% RH is standard. If the judgment is not questionable, recognize measurement at  5°C to 35°C & relative humidity, 45% to ~ 85%. Direction of motor is shaft horizontal.

4.   Mechanical specifications

Items

Specifications

Condition & Remarks

4-1

Configuration

As specified in outline drawing

Outline drawing No:  Z4TL2B1240641.

4-2

Appearance

There shall be no evidence of mechanical damage and shall not have inadequate corrosion and so on.

Visual examination: Inspection carried out on samples.

4-3

Shaft end play

0.05 mm ~ 0.2 mm Max

 

4-4

Holding strength of vibration weight

30N (3kgf)  Min

 

 

5.    Performance and characteristics

 

Items

Specifications

Condition & Remarks

5-1

Rated speed

15,500 ± 2,500 rpm

At rated voltage and rated load (Counter weight).

5-2

Rated current

95mA max

5-3

Stall current

130mA max

At rated voltage.

5-4

Starting voltage

2.0V DC max

At rated load (vibration weight) any position of rotor.

5-5

Insulation resistance

1MΩ min

At DC 100V between the lead wires and motor body.

5-6

Terminal resistance

29Ω (± 20%)

At 20°C.

5-7

Mechanical noise

50db (A) max

 

 

 

Measured at rated voltage and rated load (vibration weight).

Background noise: 28db (A) max. @ 10cm.

Measuring instruments: B & K.

The weight of jig: 700g.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.   Reliability Test

Items

Standard test conditions

Condition & Remarks

6-1

Life test

 

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-1.

Position Horizontal
Voltage Rated
Load Weight
Temperature 20°C
Humidity 65%
Life (cycles) 200,000

6-2

Low temperature exposure test

Temperature:    -40±2°C

Time:                96hrs

After the test motors shall be approved as specified in item 7-2.

6-3 High temperature exposure test

Temperature:    85±2°C

Time:                96hrs

6-4 High humidity exposure test

Temperature:            40±2°C

Humidity:                  90~95% RH

Exposure time:          96hrs

No condensation of moisture

6-5

Vibration test

Displacement:    1.5 mm (p-p)

Frequency: 10 to 55 Hz
Period:
20 Minutes log sweep (10~55~10 Hz)
Direction: x, y, z
Time: Each 2 hours

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Set the motor to the approximately 100g (include the motor) weight of block drop the motor on the concrete floor.

Height:                1.5 meters

Direction:             ±x, ±y, ±z

Number of times:   Twice 2 each

After the test motors shall be approved as specified in item 7-2.

6-7

Heat stock test

 

 

After the test motors shall be approved as specified in item 7-2.

 

7.  Requirements

Items

Requirements

7-1

Table A

1) Rated speed:                         Initial data -30% min./ +60% max.

2) Rated current:                        Initial data ±30% max

3) Starting voltage:                    2.4V DC max

7-2

Table B

1) Rated speed:                         Initial data -30% min./ +30% max.

2) Rated current:                       Initial data ±30% max

3) Starting voltage:                   2.4 V DC max

 

8. Caution and Matters

 

8-1 (Please lay the motors carefully in transportation to avoid any serious damage to the motor body or its electric function because of collision.)


8-2 (Please use the motor according to the instruction of this product specification, or else, it will be bad for motor's life.)


8-3 (Make arrangement to limit the storage period to 6 months or less. Please do not store motor in high temperature. Low temperature. high humidity environment. Condensation of atmosphere must be avoided in motor usage or opening the packaging of the motor.)


8-4 (For proper operation. storage and operating environment must not contain corrosive gases. For example H2S. SO2. NO2. CL2. etc. In addition storage environment must not have materials that emit corrosive gases especially from silicon. cyanic. formalin and phenol group. In the mechanism or the set. existence of corrosive gases may cause no rotation in motor.)


8-5 (Please don't stall the shaft for a long time after powering, and not to touch the weight when motor is rotating.)


8-6 (There should be no sundries (such as grain, fibre, hair, small tape, glue etc.) in the shaft end play.)

  

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us