1. General
scope
1-1 The specifications
apply to the coreless cylindrical permanent magnetic
micro vibration motor
DC model
4TH3-3002B30.
2. Operating
conditions
|
Items
|
Specifications
|
Condition
& Remarks
|
|
2-1
|
Rated voltage
|
3.0V
DC
|
|
|
2-2
|
Rated load
|
Counter
weight
|
As specified
in the outline drawing.
|
|
2-3 |
Rated speed |
10,500 rpm Min |
|
|
2-4
|
Rotation |
C.W. (clockwise)
|
|
|
2-5
|
Motor
position
|
All positions
|
|
|
2-6 |
Operating
voltage
|
2.2~3.6V DC
|
|
|
2-7
|
Operating
conditions
|
-20 ~ 60°C,
ordinary humidity
|
No
condensation of moisture.
|
|
2-8
|
Storage
conditions
|
-40 ~ 85°C,
ordinary humidity
|
No condensation of
moisture. |
3. Measuring
conditions
|
Items
|
Specifications
|
Condition
& Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor
position
|
Motor shaft
horizontal
|
Lock the
motor in a test fixture.
|
3-4
All data
are based on the measuring conditions: Temperature,
20°C; Humidity, 65% RH. If any disagreement occurs,
such test conditions are available: Temperature,
5~35°C; Humidity, 45 ~ 85% RH.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition
& Remarks
|
|
4-1
|
Configuration
|
As specified
in outline drawing
|
Outline drawing No:
4TH3-3002B30.
|
|
4-2
|
Appearance
|
There shall
be no evidence of mechanical damage and shall not
have inadequate corrosion, etc.
|
Visual
examination: Inspection carried out on samples.
|
|
4-3
|
Shaft end
play
|
0.3
Max |
|
|
4-4
|
Weight of
motor
|
1.0±0.02g
approx.
|
|
|
4-5
|
Holding
strength of vibration weight
|
49N (5kgf)
|
|
5. Performance
and characteristics
|
Items
|
Specifications
|
Condition
& Remarks
|
|
5-1
|
Rated speed
|
10,500rpm
|
At rated
voltage and rated load (vibration weight).
|
|
5-2
|
Rated current
|
95mA
max
|
|
5-3
|
Stall current
|
125mA
max
|
At rated
voltage.
|
|
5-4
|
Starting
voltage
|
2.0V
DC max
|
At rated load
(vibration weight) any position of rotor.
|
|
5-5
|
Insulation
resistance
|
1MΩ min
|
At DC 100V
between the lead wires and motor body.
|
|
5-6
|
Terminal
resistance
|
30Ω
approx.
|
At 20°C.
|
|
5-7
|
Mechanical
noise
|
45db (A) max
|
|
|
Measured at rated voltage and rated load
(vibration weight).
Background noise: 28db (A) max. @ 10cm.
Measuring instruments: B & K.
The weight of jig: 700g.
|
|

|
6.
Reliability Test
|
Items |
Standard test conditions |
Condition & Remarks |
|
6-1
|
Life
test |

|
After 2 hours exposure in ordinary Motors shall be
approved as specified in item 7-1. |
|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
Counter weight |
20
ºC |
65
% |
200,000 cycles |
|
40
ºC |
9 0
% |
40,000 cycles |
|
|
6-2 |
Low
temperature exposure test |
Temperature: -40±2°C
Time: 96hrs
|
After the test motors shall be approved as
specified in item 7-2. |
|
6-3 |
High
temperature exposure test |
Temperature: 85±2°C
Time: 96hrs
|
|
6-4 |
High
humidity exposure test |
Temperature: 40
Humidity: 90% RH
Exposure time: 96hrs
No condensation of moisture |
|
6-5
|
Vibration test |
Displacement: 3 mm, 100cpm
Period: 30 Mins
Direction: x, y, z
Time: Every 2 hours |
After the test motors shall be approved as
specified in item 7-2. |
|
6-6
|
Free Fall |
Set the motor to the
approximately 75g (include the motor) weight of
block drop the motor on the concrete floor.
Height: 1.5
meters
Direction: ±x, ±y,
±z
Number of times: Twice each
Shock:
29,420Nm/s2 Equivalent(3,000G)
|
After the test motors shall be approved as
specified in item 7-2. |
|
6-7
|
Heat
stock |
Circulate Condition:3 V
voltage
2s ON, 1s OFF
Time: 2 Times |
After the test motors shall be approved as
specified in item 7-2. |
7. Post environmental
|
Items
|
Requirements |
|
7-1 |
Table A |
1) Rated speed: Initial
data -30% min./ +60% max.
2) Rated current: Initial
data ±30% max
3) Insulation resistance: 1MΩ min
4) Starting voltage: 2.0V DC
max
5) Current
waveform: Normal
|
|
7-2 |
Table B |
1) Rated speed: Initial
data -30% min./ +60% max.
2) Rated current: Initial
data ±30% max
3) Starting voltage: 2.0V DC max
|
|
8. Matters to be paid attention
to when using motor
8-1 Lay the motors carefully in transportation to
avoid any damage to the motor body or its electric
function because of collision.
8-2 Storage temperature: 20±10°C. Do not leave
the motors in the environment of high temperature,
high humidity and gas that will cause rust and
corrosion. Do not store the motors for over 6
months.
8-3 Please do not lock the motor shaft when the
electric power is supplied.
8-4 Please do not touch the weights when motor is
rotating. |
|