1. General scope
1-1 The specifications apply to the
coreless cylindrical permanent magnetic micro vibration motor
DC model Z4NC1A1591901.
1. Standard Condition
1-1 Standard Voltage
1.3V DC
1-2 Voltage Range 1.1~1.5V DC
1-3 Standard Load Counter weight
R2.3x4L
1-4 Rotating Direction C.W. from the direction of the
Counter weight
1-5 Moving temp. range -10˚C~+60˚C
1-6 Storage temp. range -40˚C~+85˚C(temp. 20˚C, relative
humidity 65% RH, pressure 1013hPa)
1-7 Motor position All direction
2. Measuring
Condition
2-1 Motor position Horizontal
2-2 Current DC stabilized current
2-3 Temp/Humidity Principle measurement 5˚C~35˚C,
relative humidity
30%~90%. For abnormalities,
20˚C±2˚C, 65%±5%
2-4 Rotating direction C.W. from the direction of the
counter weight (CW)
3. Electrical Features
3-1 Standard loaded rotation 10000±2500
rpm(under Standard Voltage and load)
3-2 Standard loaded current 125 mA Max
(under Standard Voltage and load)
3-3 Starting current 145 mA Max
(under Standard Voltage)
(Locked current) (2/3R extreme resisting rate)
Not in the position which
the brushes contact the
commutator at two points
3-4 Standard loaded Starting Under loaded condition towards CW,
rotor shall move in
Voltage all positions at
1.1V
(counter weight is turned
360° slowly )
3-5 Insulation resistance Under 50VDC,1MΩ Min between motor
terminal and case
3-6 Voltage Insulation Under 50V AC, without
irregularities in 1 min between motor terminal and case
3-7 Electrical noise Using ring varistor
3-8 Wiring resistance 2/3 between poles
10.0Ω±2.0Ω
3-9 Mechanical noise 50dB(A) max from 10cm
Background noise:28dB(A)
max

4. Mechanical Structure
4-1 Appearance External measurement which should
be within the
difference accordance,
Should not show Scratches,
damages or loosening of
the grip
4-2 End play of shaft 0.30mm or less
4-3 Weight
Approximately 1.2g
4-4 Weight of counter weight Approximately
0.6g
5. Environment specification
5-1 Vibration Test Under packaged condition and
vibration range of
1.5mm cycle, subjecting to
continuous speed change
of 2mm or more during
3mins or less.
Should satisfy item 3 & 4
even in additional of 30 mins
with vibration of
1200~3300times/min.
5-2 Shock Test Inserting motor into a 6 sides
simulated box (appx 60g),
drop from 1.2m high on a
concrete & metal surfaces and
satisfying item 3 & 4
Drop times: two drops per
plane for a total of 12 drops
5-3 Storage Test
Temperature cycle (without presence of condensation on the motor)

After exposure for 24Hrs and satisfy item
3 and 4
5-4 Counter weight High Temperature Test
No vividly remarkable corrosion at 60˚C 90% HR after 250Hrs
5-5 Pull Test
Counter weight pull (Under normal temperature and humidity)
Counter weight must withstand axial pull of 3 kgf to destruct.
6. Life Test

Input
voltage: 1.3V DC
Counter weight:
R2.3×4L appx 0.6g
(C) High temperature exposure at 60˚C, 20%
RH
(D) Standard verification
(1) Variety rate of standard
rotation is less than +30%/-20% from initial.
(2) Variety rate of standard
current is less than +20%/-30% form initial.
6-1 Temperature Shock Life Test
(B)To maintain (A) cycle for 140hrs in the process of temperature shock
(D)To satisfy the standard specification
6-2 High Temperature Exposure Life Test
(C)To maintain (A) cycle under high temperature for 48hrs
(D)To satisfy the standard specification
7. Reflow
recommendations
7-1
Technical requirements for reflow
Solder
joint peak temperature: 250˚C.
Exceeding
this temperature will result in shorting and dead spot failures.
Excessive
heat weakens the magnets and it is also possible that the coating.
on the magnet wires melts causing a short in the
motor.
Liquid Line (220˚C) over time: 30 ~ 90
seconds
Requests temperature: 165˚C ~ 217˚C
<100 seconds
Preheat temperature requirements (<160˚C):
≤ 2˚C/ sec
Peak temperature rise requirements: 1˚C ~
3˚C / sec
8 . Packing Condition
8-1 Smallest packing condition

8 -2
Cardboard Packing Condition

8 -3
Final Packing Condition

9 . Others
9-1 Whatever items which be not stated in this specification will be
not guaranteed.
9-2 Do not subject the motor under locked condition for long times.
9-3 Output test date and Cpk will be
attached (n-35) of follows:
Loaded
rotation rpm
Loaded current mA
Lock current (Starting Current) mA
Starting voltage V (without consideration of Cpk value)
|