1. General scope
1-1
The specifications
apply to the coreless cylindrical permanent magnetic micro vibration
motor
DC model
Z6DL2A0765217.
2. Operating conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
1.3V DC
|
|
|
2-2
|
Rated load
|
Counterweight
|
As specified in the outline drawing.
|
|
2-3
|
Direction of Rotation
|
C.W. (clockwise)
|
|
|
2-4
|
Motor position
|
All positions
|
|
|
2-5
|
Operating voltage
|
0.9 ~ 1.6V
DC
|
|
|
2-6
|
Operating conditions
|
-30 ~ 70°C, ordinary humidity
|
No condensation of moisture.
|
|
2-7
|
Storage conditions
|
-40 ~ 80°C, ordinary humidity
|
No condensation of moisture.
|
3. Measuring conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Shaft horizontal
|
Lock the motor in a test fixture.
|
All data are based on
the measuring conditions: Temperature, 20°C and Humidity, 65% RH.
However, the
ranges of temperature 5~35°C
and humidity 45~85 %RH are to be applicable as long as no problems.
4. Mechanical
specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified in outline drawing
|
Outline drawing No:
Z6DL2A0765217. |
|
4-2
|
Appearance
|
There shall be no evidence of
mechanical damage and shall not have inadequate corrosion, etc.
|
Visual examination: Inspection carried
out on samples.
|
|
4-3 |
Shaft end play |
0.1~0.3mm |
|
|
4-4 |
Holding strength of counterweight |
49N (5kgf) Min |
|
5. Performance and
characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
10,000±1500rpm
|
At rated voltage and rated load
(vibration weight).
|
|
5-2
|
Rated current
|
230mA
max
|
|
5-3
|
Stall current
|
310mA
max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
0.7V
DC max
|
At rated load (vibration weight) any
position of rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between the lead wires and
motor body.
|
|
5-6
|
Terminal resistance
|
3.6Ω
±20% |
At 20°C.
|
6. Caution and Matters
6-1 Please lay it carefully in
transportation to avoid any damage to the unit because of collision.
6-2 Please do not leave it in the
environment of high temperature, high humidity or corrosive gas, in case
it would cause rust and corrosion to the unit.
6-3 Storage temperature: 20±10°C
7. Declaration on RoHS
Compliant
 |