1. General scope
1-1
The specifications apply to the coreless cylindrical permanent magnet motor DC
model Q6DC3 series.
2. Operating conditions
|
Items
|
Specifications
|
Condition
& Remarks
|
|
2-1
|
Rated
voltage
|
See
Item 8
|
|
|
2-2
|
No
load speed
|
See
Item 8
|
|
|
2-3
|
Direction
of rotation
|
C.W.
(clockwise)
|
|
|
2-4
|
Motor
posture
|
All
positions
|
|
|
2-5
|
Operating
voltage
|
0.9
~ 1.6V DC
|
|
|
2-6
|
Operating
conditions
|
-20 ~
60°C, 10 ~ 90% RH
|
|
|
2-7
|
Storage
conditions
|
-40 ~
80°C, 5 ~ 95% RH
|
No
condensation of moisture.
|
3. Measuring
conditions
|
Items
|
Specifications
|
Condition
& Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(65±5%)
RH
|
|
|
3-3
|
Motor
posture
|
Motor
shaft horizontal
|
Lock
the motor in a test fixture.
|
3-4
All data are based on the measuring conditions: 20°C, 65% RH. If any
disagreement occurs,
such test conditions are available:
5 ~35°C, 45 ~ 85% RH.
4. Mechanical specifications
|
Items
|
Specifications
|
Condition
& Remarks
|
|
4-1
|
Configuration
|
As
specified in outline drawing
|
Outline drawing No: Q6DC3
|
|
4-2
|
Appearance
|
No
evident mechanical damage and inadequate corrosion.
|
Visual examination on
samples.
|
|
4-3
|
Shaft end play
|
0.1 ~ 0.3mm
|
|
|
4-4
|
Weight of motor
|
1.30g approx.
|
|
5.
Performance and characteristics
|
Items
|
Specifications
|
Condition
& Remarks
|
|
5-1
|
No load speed
|
See
Item 8
|
At rated voltage
|
|
5-2
|
No load current
|
See
Item 8
|
At rated voltage
|
|
5-3
|
Stall current
|
See Item 8
|
At rated voltage
|
|
5-4
|
Starting voltage
|
See Item 8
|
|
|
5-5
|
Terminal resistance
|
See Item 8
|
At 20°C
|
|
5-6
|
Mechanical noise
|
35db avg./ 50db (A) max
|
|
6. Reliability Test
|
Items
|
Standard test conditions
|
Condition
& Remarks
|
|
6-1
|
Life test
|
Voltage:
1.3V DC
Temperature:
20±2°C
Humidity:
65±5% RH
Test
mode 1: continuous run, 100 hours
Test
mode 2: 8s on/ 8s off, 20000 cycles
|
After 2 hours exposure in
ordinary Motors shall be approved as specified in item 7-1.
|
|
6-2
|
Low temperature exposure
test
|
Temperature:
-20±2°C
Time:
96hrs
|
After 2 hours exposure in
ordinary Motors shall be approved as specified in item 7-2.
|
|
6-3
|
High temperature exposure
test
|
Temperature:
60±2°C
Time:
96hrs
|
|
6-4
|
High humidity
exposure test
|
Temperature:
40±2°C
Humidity:
90±5% RH
Exposure time:
96hrs
Dry time:
4hrs
No condensation of moisture
|
|
6-5
|
Drop test
|
Set the motor to the
approximately 75g
(include
the motor) weight of block drop
the motor on the concrete
floor.
Height:
1.2 meters
Direction:
±x, ±y, ±z
Times:
Each 2 times
|
After the test motors shall
be approved as specified in item 7-2
|
7.
Post environmental
|
Items
|
Requirements
|
|
7-1
|
Table
A
|
1) No
load speed:
Initial data -30% min./ +60% max.
2) No
load current:
Initial data ±30% max
3)
Starting voltage:
0.9V DC max
4)
Wave of current:
No blot wave.
|
|
7-2
|
Table
B
|
1) No load speed:
Initial data -30% min./ +60% max.
2) No load current:
Initial data ±30% max
3)
Starting voltage:
0.9V DC max
|
8. Main specifications
Q6DH3
Series
|
Part
Number
|
Color
of Cover
|
Nominal
Voltage
|
Starting
Voltage
|
Current
|
Normal
Speed
|
Starting
Current
|
Armature
Resistance
|
|
V
DC.
|
V
DC.
|
Avg.
(mA)
|
Max.
(mA)
|
rpm
|
mA
|
Ω±3%
|
|
Q6DC3-1.0A
|
blue
|
1.3
|
0.8
|
15
|
25
|
10000±3000
|
<70
|
20.5
|
|
Q6DC3-1.4A
|
black
|
1.3
|
0.6
|
25
|
30
|
14000±3000
|
<130
|
10.5
|
|
Q6DC3-1.6A
|
green
|
1.3
|
0.6
|
30
|
35
|
16000±3000
|
<150
|
8.5
|
|
Q6DC3-1.9A
|
brown
|
1.3
|
0.6
|
32
|
45
|
19000±3000
|
<190
|
6.0
|
|
Q6DC3-2.2A
|
rose
|
1.3
|
0.6
|
40
|
50
|
22000±3000
|
<265
|
3.6
|
|
Q6DC3-2.4A
|
yellow
|
1.3
|
0.6
|
45
|
55
|
24000±3000
|
<285
|
3.2
|
|
Q6DC3-2.6A
|
purple
|
1.3
|
0.6
|
45
|
60
|
26000±3000
|
<305
|
3.0
|
|
Q6DC3-2.8A
|
pink
|
1.3
|
0.6
|
50
|
70
|
28000±3000
|
<327
|
2.8
|
Q6DH3-X
Series
|
Part Number |
Nominal Voltage |
Starting Voltage |
Current |
Normal Speed |
Stall Current |
Armature Resistance |
|
V DC. |
V DC. |
mA |
rpm |
mA |
Ω±3% |
|
Q6DC3-2.0AX |
1.3 |
0.6 Max |
50 Max |
20,000±3000 |
320 Max |
2.7 |
|
Q6DC3-2.7AX |
1.3 |
0.6 Max |
85 Max |
27,000±3000 |
420 Max |
1.63 |
|
Q6DC3-3.4AX |
1.3 |
0.6 Max |
110 Max |
34,000±3000 |
540 Max |
1.25 |
9. Cautions and matters
9-1 Warnings:
In a motor near the end its life, or under breakdown conditions, short circuits
can develop between commutator segments. Uncontrolled voltage may then leak into
the power source circuit. Motors may overheat or fail if run continuously with
its rotor locked condition or under excessive loads.
9-2
Destructive atmospheres: Do not
use and store the motor in the corrosive gas atmosphere (H2S, SO2,
NO2, Cl2, etc.), or substances that can emit toxic gases,
such as organic silicon, cyanide, formalin, or phenol compounds. The motor may
get serious damages.
9-3
Condensation: Condensation on
the electrical circuits can destroy the motor or control circuits. Monitor the
environment and undertake measures to prevent condensation, such as installing
condensation sensors to cut power when necessary.
9-4 Some
particular plastic materials can crack and fail after exposure to motor bearing
oil. Perform test the motor in/on the subassembly to check the influence of the
oiled plastic parts.
9-5
Avoid connecting a serial resistor to the motor if at all possible, as this can
negatively affect reliability. If this is unavoidable, keep resistance as low as
possible and test thoroughly for reliability before using.
9-6
When testing for UL, CSA or other safely standards, apply for approval for the
entire subassembly.
9-7
Do not store motors under conditions of extreme temperatures or high humidity,
or for longer than six months even room conditions. When removing out of
packaging after storage, take precautions to prevent condensation.
9-8
Please consults us in advance when design considerations call for forcefully
stalling the motor using a short circuit at the terminal or reverse voltage.
Such operations can shorten product life.
|