VibratorMotor.com

VibratorMotor.com

Home     |     Product Info    |     About us     |     Factory tour     |    ISO Certifications    |    RoHS Info    |    Sample Request    |    Contact us   

 

Part No.    C1030B200F

           Click to Download PDF Format !

 

 

 

 

 

......................................................................................................................................................................................................

 

1.  Application

       This specification applies to flat permanent-magnetic motors DC model C1030B200F.

 

2.  Operating condition

Item

Specification

2-1

Rated voltage

3.0 V DC

2-2

Operating voltage

2.7~3.3 V DC

2-3

Rotation

CW(clockwise) or CCW(counter clockwise)

2-4

Operating environment

-20°C ~+60°C ,Ordinary Humidity:65±20%RH

2-5

Storage environment

-30°C ~+70°C ,Ordinary Humidity:65±20%RH

 

3.  Test condition

Item

Specification

Conditions

3-1

Temperature

25±3°C

3-2

Humidity

65±20% RH

3-3

Power supply

DC power supply 3.0V

 

4.  Electrical initial characteristics

Item

Specification

Condition

4-1

Rated speed

9,000rpm Min

At rated voltage

4-2

Rated current

100 mA Max

At rated voltage

4-3

Starting current

120 mA Max

At rated voltage

4-4

Starting voltage

2.3 V DC Max

Motor is rotating at min starting voltage.

4-5

Insulation resistance

10 MΩ Min

At DC 100 V between lead wire and case.

4-6 Terminal resistance 32Ω±15%(single posture)
62Ω±15%(compose posture)
At 25°C

 

5.  Mechanical characteristics

Item

Specification

5-1

Bracket deflection strength

9.8 N or more

5-2

Mechanical noise

50 dB(A)Max

At rated voltage, back ground noise 28dB(A) Max

 

 

6.       Reliability Tests

Item

Specification

Requirements

6-1

Lifetime

  Rated voltage: 3.0V DC

 Test mode: 2s On, 2s Off. as one cycle.

 Test cycle: 50,000 cycles

After the test, motors shall be approved as specified in item 7-1.

6-2

Low temperature exposure

Temperature : -30°C

Time            : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified as specified in item 7-2.

6-3

High temperature exposure

Temperature : +70°C

Time            : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified as specified in item 7-2.  

6-4

High Humidity exposure

Temperature : +40°C

Humidity        : 95%RH

Exposure time : 96 h   

No condensation of moisture

After 4 hours exposure in ordinary temperature and humidity, Motors shall be approved as specified in item 7-2. 

6-5

Vibration

Displacement:     1.5mm (p-p)

Frequency:        10~55Hz

Acceleration:      22m/s2

Period: 10 Minutes log sweep

                  (10~55~10Hz)

Condition    : Samples shall be applied for a period of 10 minutes in 3 axial directions.

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Test mode: Set the motor to a fixture of  approximately 100 g (include the motor) and drop onto the concrete floor.

Height        :1.5 m

Direction     : ±x, ±y, ±z

Number of times: Each 3 times

After the test motors shall be approved as specified in item 7-2.

6-7

Thermal stock

    Test mode: 1 hour at -4040°C, 1 hour at +85°C, as one cycle. Transfer time between extreme temperatures: <5  min/Test cycle: 15 cycles

      

After 4 hours exposure in ordinary temperature and humidity, Motors shall be approved as specified in item 7-2.   

 

7.    Requirements

Item

Requirements

7-1

Table A

1) Rated speed:        No lower than -30% of initial data;
                             No more than +50% of initial data.

2) Rated current:      No lower than -30% of initial data;
                             No more than +50% of initial data.

3) Terminal resistance: 

                             No more than +15% of initial data;

                             No less than -15% of initial data.

4) Starting voltage:  2.5V DC Max

5) Insulation resistance: 10 MΩ/ 10 MΩ Min

7-2

Table B

1) Rated speed:      No more than +20% of initial data;
                           No less than -20% of initial data.

2) Rated current:    No more than +20% of initial data;
                           No less than -20% of initial data.

3) Starting voltage: 2.5 V DC Max

4) Terminal resistance: 

                           No more than +15% of initial data;

                           No less than -15% of initial data.

 

8.   Caution for Use

8-1 Unless it is used in accordance with the specifications ,the performance and life may be considerably reduced . Due attention should be paid to voltage and range for use

8-2 Avoid use or save the coin motor in the following environment.

- High temperature and high humidity area.

- Corrosive gas such as H2S, SO2, NO2, Cl2.

- Dusty area.

8-3 Due attention must be paid to the handling and working environments because such objects as iron powder if attracted by the coin motors magnet, will cause noise, characteristic deterioration thus reducing the reliability.

8-4 Please confirm enough no problem of standards and laws and ordinances on your cellular.

8-5 To handle the coin motor ,hold the motor case softly.

8-6 Rust of plate (steel) and similar edge should be OK.

 

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us

Copyright 2010  ©  VibratorMotor.com