1.
General scope
1-1
This specification applies to cylindrical
permanent magnetic DC vibration motor model
Z7AL2H1692082.
2.
Operating conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
1.5V
DC
|
|
|
2-2
|
Rated load
|
Counter weight
|
As specified in 10. Outline
drawing.
|
|
2-3
|
Rotation
|
C.W/C.C.W
(clockwise or counter
clockwise)
|
|
|
2-4 |
Motor position
|
All positions
|
|
|
2-5
|
Operating voltage
|
1.0 ~ 1.8V DC
|
|
|
2-6 |
Operating conditions
|
-30 ~ 70°C, ordinary
humidity
Humidity :65±20%RH |
No condensation of moisture.
|
|
2-7
|
Storage conditions
|
-40 ~ 80°C, ordinary
humidity
Humidity :65±20%RH |
No condensation of moisture.
|
3.
Measuring
conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Motor Shaft horizontal
|
Lock the motor in a test
fixture.
|
The measurement at 20 & 65%RH is standard. If
the judgment is not questionable, recognize measurement at 5
to 35 & relative humidity 45% to 85%. Direction of motor is
shaft horizontal.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified in 10. Outline
drawing
|
Outline drawing No:
Z7AL2H1692082.
|
|
4-2
|
Appearance
|
There shall be no evidence of mechanical
damage and shall not have inadequate corrosion and so on |
Visual examination (allowable extent is
based on boundary sample) |
|
4-3
|
Shaft end play
|
0.1 ~ 0.3mm
|
|
|
4-4 |
Holding strength of
vibration weight
|
49N (5kgf) min. |
|
5.
Performance and
characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
12,500±2,500rpm
|
At rated voltage and rated
load (Counterweight).
|
|
5-2
|
Rated current
|
370mA
max
|
|
5-3
|
Stall current
|
1000mA
max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
1.0V
DC max
|
(Counterweight) any position
of rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between terminal
and case.
|
|
5-6
|
Terminal resistance
|
1.6Ω approx.
(±20%) |
At 20°C.
|
|
5-7
|
Mechanical noise
|
50db (A) max
|
|
|
Measured at rated voltage
and rated load (counterweight).
Background noise: 28db (A)
max. @ 10cm.
Measuring instruments: B &
K.
The weight of jig: 700g.

|
6.
Reliability Test
|
Items
|
Standard test conditions
|
Condition & Remarks
|
|
6-1
|
Life test
|

|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
weight |
20 ºC |
65 % |
200,000 cycles |
|
After 2 hours exposure in
ordinary temperature and
humidity, Motors shall be
approved as specified in item 7-1. |
|
6-2
|
Low Temp
exposure |
Temperature: -40±2°C
Time:
96hrs
|
After 2 hours exposure in
ordinary temperature and
humidity, Motors shall be
approved as specified in item 7-2. |
|
6-3
|
High Temp
exposure |
Temperature: 60±2°C
Time:
96hrs
|
|
6-4
|
Humidity exposure
|
Temperature: 40±2°C
Humidity: 90 ~
95% RH
Exposure time: 96hrs
No condensation of moisture
|
|
6-5
|
Vibration |
Displacement:
1.5mm (p-p)
Frequency: 10 ~
55Hz
Acceleration: 22m/s2
Period: 20
Mins log sweep
(10 ~ 55 ~ 10Hz)
Direction: x, y,
z
Time:
Every 2 hours
|
After the test motors shall
be approved as specified in item 7-2.
|
|
6-6
|
Free fall
|
Test state: Set the motor to the approximately 75 g
(include the motor) weight of block drop the motor
on the concrete floor.
Height: 1.5 m
Direction: 6/6faces
Number of times: Twice each |
After the test motors shall
be approved as specified in item 7-2.
|
|
6-7
|
Heat shock |
Test cycle: 20 cycles
 |
After 2 hours exposure in
ordinary temperature and humidity, Motors shall be
approved as specified in
item 7-2. |
7.
Requirements
|
Items
|
Requirements
|
|
7-1
|
Table A
|
1) Rated
speed: Initial data -30% Min,
Initial data +60% Max
2) Rated
current: ±30%/Initial data±30%
max
3) Starting
voltage:
1.3 V DC max
|
|
7-2
|
Table B
|
1) Rated
speed: ±30%/Initial data±30%
max
2) Rated
current: ±30%/Initial data±30%
max
3) Starting
voltage:
1.3 V DC max
|
8.
Matters to be paid attention to
when using motor
8-1 Please lay the motors carefully in transportation to
avoid any serious damage to the motor body or its electric
function because of collision.
8-2 Please use and storage motors according to N0.2 item
(Operating Conditions) in specification, or else motor
characteristics would be affected.
8-3 Make arrangement to limit the storage period
to 6 months or less. Condensation of atmosphere must be
avoided in motor usage or opening the packaging of the motor.
8-4 For proper operation. storage and operating
environment must not contain corrosive gases. For example H2S.
SO2. NO2. CL2. etc. In addition storage environment must not
have materials that emit corrosive gases especially from
silicon. cyanic. formalin and phenol group. In the mechanism
or the set. existence of corrosive gases may cause no rotation
in motor.
8-5
Please don't stall the shaft for a
long time after powering, and not to touch the weight when
motor is rotating.
8-6
There should be no sundries (such
as grain, fibre, hair, small tape, glue etc.) in the shaft end
play.
|