1.
General scope
1-1
This specification applies to cylindrical permanent magnetic DC vibration motor
model
Z7AL2B1690002.
2.
Operating conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
2-1
|
Rated voltage
|
3.0V DC
|
|
|
2-2
|
Rated load
|
Counter weight
|
As specified in 10. Outline drawing.
|
|
2-3
|
Rotation
|
C.W/C.C.W
(clockwise or counter
clockwise)
|
|
|
2-4
|
Motor position
|
All positions
|
|
|
2-5
|
Operating voltage
|
2.2 ~ 3.6V DC
|
|
|
2-6
|
Operating conditions
|
-30 ~ 70°C, ordinary humidity
Humidity :65±20%RH
|
No condensation of moisture.
|
|
2-7
|
Storage conditions
|
-40 ~ 80°C, ordinary humidity
Humidity :65±20%RH
|
No condensation of moisture.
|
3.
Measuring conditions
|
Items
|
Specifications
|
Condition & Remarks
|
|
3-1
|
Temperature
|
20±2°C
|
|
|
3-2
|
Humidity
|
(63 ~ 67%) RH
|
|
|
3-3
|
Motor position
|
Motor Shaft horizontal
|
Lock the motor in a test fixture.
|
3-4
All data are based on the measurement under
the temperature of 20
°C
and humidity 65 %RH. However, the
ranges of temperature 5~35°C
and humidity 45~85 %RH are to be
applicable as long as no problems.
4.
Mechanical specifications
|
Items
|
Specifications
|
Condition & Remarks
|
|
4-1
|
Configuration
|
As specified in 10. Outline drawing
|
Outline drawing No:
Z7AL2B1690002.
|
|
4-2
|
Appearance
|
There shall be no evidence of mechanical damage and shall not have
inadequate corrosion and so on
|
Visual examination (allowable extent is based on boundary sample)
|
|
4-3
|
Shaft end play
|
0.1 ~ 0.3mm
|
|
|
4-4
|
Holding strength of vibration weight
|
49N (5kgf) min.
|
|
5.
Performance and characteristics
|
Items
|
Specifications
|
Condition & Remarks
|
|
5-1
|
Rated speed
|
12,000±2,500rpm
|
At rated voltage and rated load (Counterweight).
|
|
5-2
|
Rated current
|
250mA max
|
|
5-3
|
Stall current
|
680mA max
|
At rated voltage.
|
|
5-4
|
Starting voltage
|
1.7V DC max
|
(Counterweight) any position of
rotor.
|
|
5-5
|
Insulation resistance
|
1MΩ min
|
At DC 100V between terminal and
case.
|
|
5-6
|
Terminal resistance
|
5.5Ω approx.
(±20%)
|
At 20°C.
|
|
5-7
|
Mechanical noise
|
50db (A) max
|
|
|
Measured at rated voltage and rated load (counterweight).
Background noise: 28db (A) max. @ 10cm.
Measuring instruments: B & K.
The weight of jig: 700g.

|
6. Reliability Test
|
Items
|
Standard test conditions
|
Condition & Remarks
|
|
6-1
|
Life test
|

|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
weight |
20 ºC |
65 % |
200,000 cycles |
|
After 2 hours exposure in ordinary
temperature and
humidity, Motors shall be
approved as specified in item 7-1.
|
|
6-2
|
Low
Temp
exposure
|
Temperature: -40±2°C
Time:
96hrs
|
After 2 hours exposure in ordinary
temperature and
humidity, Motors shall be
approved as specified in item 7-2.
|
|
6-3
|
High
Temp
exposure
|
Temperature: 60±2°C
Time:
96hrs
|
|
6-4
|
Humidity exposure
|
Temperature: 40±2°C
Humidity:
90 ~ 95% RH
Exposure time:
96hrs
No condensation of moisture
|
|
6-5
|
Vibration
|
Displacement: 1.5mm
(p-p)
Frequency:
10 ~ 55Hz
Acceleration:
22m/s2
Period:
20 Mins log sweep
(10 ~ 55 ~ 10Hz)
Direction:
x, y, z
Time:
Every 2 hours
|
After the test motors shall be approved as specified in item 7-2.
|
|
6-6
|
Free fall
|
Test state: Set the motor to the approximately 75
g
(include the motor) weight of block drop the
motor
on the concrete floor.
Height: 1.5 m
Direction:
6/6faces
Number of times: Twice each |
After the test motors shall be approved as specified in item 7-2.
|
|
6-7
|
Heat shock
|
Test cycle:
20 cycles
 |
After 2 hours exposure in ordinary
temperature and humidity, Motors shall be approved as specified in
item 7-2.
|
7. Requirements
|
Items
|
Requirements
|
|
7-1
|
Table A
|
1) Rated speed:
Initial data -30% Min, Initial data +60% Max
2) Rated current:
±30%/Initial data±30% max
3) Starting voltage:
2.0
V DC max
|
|
7-2
|
Table B
|
1) Rated speed:
±30%/Initial data±30% max
2) Rated current:
±30%/Initial data±30% max
3) Starting voltage:
2.0V DC max
|
8.
Matters to be paid attention
to when using motor
8-1 Please lay the motors carefully in
transportation to avoid any serious damage to the motor body or its electric function
because of collision.
8-2 Please use and storage motors
according to N0.2 item (Operating Conditions) in specification, or else motor
characteristics would be affected.
8-3 Make arrangement to limit the storage period to 6 months or
less. Condensation of atmosphere must be avoided in motor usage or opening the
packaging of the motor.
8-4 For proper operation. storage and operating environment must not
contain corrosive gases. For example H2S. SO2. NO2. CL2. etc. In addition
storage environment must not have materials that emit corrosive gases especially
from silicon. cyanic. formalin and phenol group. In the mechanism or the set.
existence of corrosive gases may cause no rotation in motor.
8-5 Please don't stall the shaft for a
long time after powering, and not to touch the weight when motor is rotating.
8-6 There should be no sundries (such as
grain, fibre, hair, small tape, glue etc.) in the shaft end play.
|