VibratorMotor.com

VibratorMotor.com

Home     |     Product Info    |     About us     |     Factory tour     |    ISO Certifications    |    RoHS Info    |    Sample Request    |    Contact us   

 

                                          Part No.    Z7AL2A1692081

                Click to Download PDF Format !

 

1.    General scope

         1-1 The specifications apply to the coreless cylindrical permanent magnetic micro vibration motor

         DC model Z7AL2A1692081.

2.   Operating conditions

Items

Specifications

Condition & Remarks

2-1

Rated voltage

1.3V DC

 

2-2

Rated load

Counter weight

As specified in 10. Outline Drawing.

2-3

Rotation

C.W. / C.C.W

(clockwise or counter clockwise)

 

2-4

Motor position

All positions

 

2-5

Operating voltage

0.9~1.6V DC

 

2-7

Operating conditions

-30 ~ 70°C, ordinary humidity

Ordinary Humidity:65±20%RH

No condensation of moisture.

2-8

Storage conditions

-40 ~ 80°C, ordinary humidity

Ordinary Humidity:65±20%RH

No condensation of moisture.

 

 

3.   Measuring conditions

 

Items

Specifications

Condition & Remarks

3-1

Temperature

20±2°C

 

3-2

Humidity

(63% ~ 67%) RH

 

3-3

Motor position

Motor shaft horizontal

Lock the motor in a test fixture.

 

 

The measurement at 20°C  & 65%RH is standard. If the judgment is not questionable, recognize measurement at 5°C  to 35°C  

& relative humidity 45% to 85%. Direction of motor is shaft horizontal.

 

4.   Mechanical specifications

Items

Specifications

Condition & Remarks

4-1

Configuration

As specified in 10. Outline Drawing

Outline drawing No:Z7AL2A1692081.

4-2

Appearance

There shall be no evidence of mechanical damage and shall not have inadequate corrosion and so on.

Visual examination (allowable extent is based on boundary sample)

4-3

Shaft end play

0.05 ~ 0.2mm

 

4-4

Holding strength of vibration weight

49N (5kgf)

 

5.    Performance and characteristics

 

Items

Specifications

Condition & Remarks

5-1

Rated speed

5,500±2000rpm

At rated voltage and rated load (Counterweight).

5-2

Rated current

70mA Max

5-3

Starting voltage

0.75V DC max

At rated load (Counterweight) any position of rotor.

5-4

Insulation resistance

1MΩ min

At DC 100V between Terminal and case.

5-5

Terminal resistance

9.6 (±20%)

At 20°C.

5-6

Mechanical noise

50db (A) max

 

 

 

At rated voltage and rated load (Counterweight).

Background noise: 28db (A) max.

Measuring instruments: B & K.

The weight of jig: 700g.

 

6.   Reliability Test

Items

Standard test conditions

Condition & Remarks

6-1

Life test

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-1.

Position

Voltage

Load

Temperature

Humidity

Life

Horizontal

Rated

Weight

20 ºC

65 %

200,000 cycles

 

6-2

Low temp exposure

Temperature:    -40±2°C

Time:               96hrs

After the test motors shall be approved as specified in item 7-2.

6-3 High temp exposure

Temperature:    60±2°C

Time:               96hrs

6-4 Humidity exposure

Temperature:    40±2°C

Humidity:          90 ~ 95% RH

Exposure time:   96hrs

No condensation of moisture

6-5

Vibration

Displacement:   1.5mm (p-p)

Frequency:       10 ~ 55Hz

Acceleration:     22m/s2

Period:             20 Mins log sweep

                      (10 ~ 55 ~ 10Hz)

Direction:          x, y, z

Time:               Every 2 hours

After the test motors shall be approved as specified in item 7-2.

6-6

Free Fall

Set the motor to the approximately 75 g (include the motor) weight of block drop the motor on the concrete floor.

Height:              1.5 meters

Direction:           ±x, ±y, ±z

Times:               Twice 2 each

After the test motors shall be approved as specified in item 7-2.

6-7

Heat stock test

Test cycle: 20 cycles

After the test motors shall be approved as specified in item 7-2.

7.  Post environmental

Items

Requirements

7-1

Table A

1) Rated speed:                          Initial data -30% min./ +60% max.

2) Rated current:                        Initial data -30% min./ +60% max.

3) Starting voltage:                    1.1V DC max

7-2

Table B

1) Rated speed:                         Initial data -30% min./ +30% max.

2) Rated current:                       Initial data -30% min./ +30% max.

3) Starting voltage:                   1.1V DC max

 

8. Matters to be paid attention to when using motor

8-1 (Please lay the motors carefully in transportation to avoid any serious damage to the motor body or its electric function because of collision.)

8-2 (Please use and storage motors according to N0.2 item (Operating Conditions) in specification, or else motor characteristics would be affected.)

8-3 (Make arrangement to limit the storage period to 6 months or less. Condensation of atmosphere must be avoided in motor usage or opening the packaging of the motor.)

8-4 (For proper operation. storage and operating environment must not contain corrosive gases. For example H2S. SO2. NO2. CL2. etc. In addition storage environment must not have materials that emit corrosive gases especially from silicon. cyanic. formalin and phenol group. In the mechanism or the set. existence of corrosive gases may cause no rotation in motor.)

8-5 (Please don't stall the shaft for a long time after powering, and not to touch the weight when motor is rotating.)

8-6 (There should be no sundries (such as grain, fibre, hair, small tape, glue etc.) in the shaft end play.)

 

  

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us

Copyright 2011  ©  VibratorMotor.com