VibratorMotor.com

VibratorMotor.com

Home     |     Product Info    |     About us     |     Factory tour     |    ISO Certifications    |    RoHS Info    |    Sample Request    |    Contact us   

 

                                                            Part No.    C1034H003F

             Click to Download PDF Format !

         

 

     1.  Application

       This specification applies to flat permanent-magnetic motors DC model C1034H003F.

 

      2.  Operating condition

Item

Specification

2-1

Rated voltage

1.5 V DC

2-2

Operating voltage

1.2~1.8 V DC

2-3

Rotation

CW (clockwise) or CCW (counter clockwise)

2-4

Operating environment

-20°C ~60°C ,Ordinary Humidity:65±20% RH

2-5

Storage environment

-30°C ~70°C ,Ordinary Humidity:65±20% RH

 

     3.  Conditions of Measurement

Item

Specification

3-1

Temperature

25±3°C

3-2

Humidity

65±20% RH

3-3

Power supply

Constant power supply 1.5V

 

      4.  Electrical characteristics

Item

Specification

Condition

4-1

Rated speed

6200~9700rpm  ( at 1.3V )

7000~10500rpm ( at 1.5V )

At rated voltage

4-2

Rated current

30mA Max   ( at 1.3V )

35mA Max   ( at 1.5V )

4-3

Starting current

60mA Max

Motor is rotating at min starting voltage.

4-4

Starting voltage

0.9 V DC Max

Motor is rotating at min starting voltage.

4-5

Insulation resistance

10 MΩ Min

At DC 100 V between lead wire and case.

4-6

Terminal resistance

32 Ω ± 15% (Single posture)

60 Ω ± 15% (Compose posture)

At 25C°

 

      5.  Mechanical characteristics

Item

Specification

5-1

Bracket deflection strength

9.8 N or more

5-2

Mechanical noise

50dB(A) Max.

At rated voltage

Back ground noise 28dB(A) Max

 

 

      6.       Durability characteristics

Item

Specification

Requirements

6-1

Lifetime

Rated voltage : 1.5 V  DC

Test mode: 2s On, 2s Off, as one cycle.

Test cycle 50,000 cycles

            

After the test, motors shall be approved as specified in item 7-1.

6-2

Low temperature exposure

Temperature : -30°C

Time           : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified in item 7-2.

6-3

High temp.

exposure

Temperature : +70°C

Time            : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified in item 7-2.

6-4

Humidity exposure

Temperature : +40°C

Humidity      : 95%RH

Exposure time : 96 h   

No condensation of moisture

After 4 hours exposure in ordinary temperature and humidity, Motors shall be approved as specified in item 7-2. 

6-5

Vibration

Displacement :    1.5mm (p-p)

Frequency:        10~55Hz

Acceleration:      22m/s2

Period: 10 Minutes log sweep  (10~55~10Hz)            

Condition    : Samples shall be applied for a period of 10 minutes in three axial direction.

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Test mode: Set the motor to the approximately 100 g (include the motor) and drop it onto the concrete floor.

Height        :1.5 m

Direction     : ±x, ±y, ±z

Number of times: Each 3 times

After the test motors shall be approved as specified in item 7-2.

6-7

Thermal shock

   

Test mode: 1 hour at -40°C, 1 hour at +85°C, as one cycle. Transfer time between extreme temperatures:< 5/5min/Test cycle: 15 cycles

After the test motors shall be approved as specified in item 7-2.

 

      7.    Requirements

Item

Requirements

7-1

Table A

1) Rated speed:           No lower than -30% of initial data;

                                No more than +50% initial data.

2) Rated current:         No lower than -30% of initial data;

                                No more than +30% initial data.

3) Terminal resistance: No lower than +15% of initial data;

                                No less than -15% initial data.

4) Starting voltage:           1.1V DC Max

5) Insulation resistance :    10 MΩ Min

7-2

Table B

1) Rated speed:          No more than +20% of initial data;

                               No less than -20% initial data.

2) Rated current:        No more than +20% of initial data;

                               No less than -20% initial data.

3) Starting voltage:           1.1V DC Max

4) Terminal resistance: No more than +15% of initial data;

                                No less than -15% initial data.

 

8.   Caution for Use

8-1 Unless it is used in accordance with the specifications ,the performance and life may be considerably reduced . Due attention should be paid to voltage and range for use.

8-2 Advice uses this motor within 6 months as a voiding as possible.

      Avoid use or save the motor in the following environment.

 

1.  High temperature and high humidity area.

2.  Corrosive gas such as H2SSO2NO2Cl2.

3.  Dusty area.

8-3 Due attention must be paid to the handling and working environments because such objects as iron powder if attracted by the motor magnet, will cause noise, characteristic deterioration thus reducing the reliability.

8-4 Please confirm enough no problems of standards and laws and ordinances on your cellular phone.

8-5 To handle the motor ,hold the motor case softly.

8-6 Rust of plate (steel) and similar edge should be OK.

 

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us