VibratorMotor.com

VibratorMotor.com

Home     |     Product Info    |     About us     |     Factory tour     |    ISO Certifications    |    RoHS Info    |    Sample Request    |    Contact us   

 

Part No.    C0834B011F

                   Click to Download PDF Format !

 

  1.   General Description

This specification applies to coin-shape permanent-magnetic motor DC model C0834B011F.

2.  Operating condition

Item

Specification

Conditions

2-1

Rated voltage

3.0V DC

2-2

Operating voltage

2.7~3.3V DC

2-3

Direction of vibration

CW(clockwise) or CCW(counter clockwise)

2-4

Operating environment

-20~+60°C, Ordinary Humidity : 65±20% RH

2-5

Storage environment

-30~+70°C, Ordinary Humidity : 65±20% RH

3.  Condition of Measurement

Item

Specification

Conditions

3-1

Temperature

25±3°C

3-2

Humidity

65±20% RH

3-3

Power supply

DC power supply 3.0V

4.  Electrical initial characteristics

Item

Specification

Conditions

4-1

Rated speed

12000±3000 rpm

At rated voltage

4-2

Rated current  

100mA Max

4-3

Starting current

120 mA Max

Motor is rotating at min starting voltage.

4-4

Starting voltage  

2.3V DC Max

4-5

Insulation resistance:

10MΩ Min

At DC 100 V between lead wire and case.

4-6 Terminal resistance

29Ω±15% (single posture)

48Ω±15% (compose posture)

25°C

25°C

5.  Mechanical characteristics

Item

Specification

Conditions

5-1

Bracket deflection strength

9.8N

9.8N or more

5-2

Mechanical noise

50dB (A) Max  

At rated voltage. Back ground noise 28dB(A) Max

 

6.  Reliability Tests

Item

Specification

Requirements

6-1

Life test

          

 

 Test cycle 50,000 cycles

After the test, motors shall be approved as specified in item 7-1.

6-2

Low temperature exposure

Temperature : -30°C

Time        : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified in item 7-2.

6-3

High temperature exposure

Temperature : +70°C

Time        : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified in item 7-2.  

6-4

Humidity exposure

Temperature : +40°C  

Humidity       : 95%RH

Exposure time : 96 h   

No condensation of moisture

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified in item 7-2.  

6-5

Vibration

Frequency:        10~55Hz

Acceleration:      22m/s2

Period: 10 Minutes log sweep

             (10~55~10Hz)

Condition    : Samples shall be applied for a period of 10 minutes in three axial directions.

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Set the motor to the approx. 100g  (include the motor) weight of block, and drop the motor onto the concrete floor.

Height   :1.5m

Direction  : ±x, ±y, ±z

Number of times: Each 3 times

After the test motors shall be approved as specified in item 7-2.

6-7

Thermal shock

    Test mode: 1 hour at -40°C, 1 hour at +85°C, as one cycle.
Transfer time between extreme temperatures:<5 分/5min
Test cycle: 15 cycles 

After the test motors shall be approved as specified in item 7-2.

 

7.    Judgments after Reliability Tests

Item

Specification

7-1

Table A

1) Rated speed:                    No lower than -30% of Initial data

                                          No more than +50% of Initial data

2) Rated current:                  No lower than -30% of Initial data

                                         No more than +50% of Initial data

3) Terminal resistance :          10MΩ Min

4) Starting voltage:               2.5V DC Max

5) Insulation resistance:         10MΩ / 10MΩ Min

7-2

Table B

1) Rated speed:                   No more than +20% of Initial data

                                        No less than -20% of Initial data

2) Rated current:                 No more than +20% of Initial data

                                        No less than -20% of Initial data

3) Starting voltage:                   2.5V DC Max

4) Terminal resistance :        No more than +15% of Initial data

                                        No less than -15% of Initial data

8.   Caution for Use

8-1   Unless it is used in accordance with the specifications, the performance and life may be considerably reduced .

        Due attention should be paid to voltage and range for use.

8-2   Avoid use or save the motor in the following environment.
       1. High temperature and high humidity area
       2. Corrosive gas such as H2S, SO2, NO2, Cl2.
       3. Dusty area.

8-3   Due attention must be paid to the handling and working environments because such objects as iron powder

        if attracted by the motor magnet, will cause noise, characteristic deterioration thus reducing the reliability.

8-4   Please confirm enough no problem of standards and laws and ordinances on your cellular phone.

8-5  To handle the motor ,hold the motor case softly.

8-6  Rust of plate (steel) and similar edge should be OK.

 

 

 

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us

Copyright 2010  ©  VibratorMotor.com