Home | Product Info | About us | Factory tour | ISO Certifications | RoHS Info | Sample Request | Contact us |
|||
|
Part No. Z6SH1A0060711 ( Old Part Number : 6SH1-0671A ) |
|
1.
General scope
1-1
The specifications apply
to the coreless cylindrical permanent magnetic micro vibration motor DC
model Z6SH1A0060711.
2. Operating conditions
3-4 All data are based on the measuring conditions: Temperature, 20°C; Humidity, 65% RH. If any disagreement occurs, such test conditions are available: Temperature, 5~35°C; Humidity, 45 ~ 85% RH. 4. Mechanical specifications
5.
Performance and characteristics
6. Reliability Test
7. Post environmental
8.
Caution and Matters
8-1 Warnings: In a motor near the end its life, or under
breakdown conditions, short circuits can develop between commutator
segments. Uncontrolled voltage may then leak into the power source circuit.
Motors may overheat or fail if run continuously with its rotor locked
condition or under excessive loads.
8-2 Destructive atmospheres: Do not use and store the motor
in the corrosive gas atmosphere (H2S, SO2, NO2,
Cl2, etc.), or substances that can emit toxic gases, such as
organic silicon, cyanide, formalin, or phenol compounds. The motor may get
serious damages.
8-3 Condensation: Condensation on the
electrical circuits can destroy the motor or control circuits. Monitor the
environment and undertake measures to prevent condensation, such as
installing condensation sensors to cut power when necessary.
8-4 Be aware of the following factors
and perform necessary tests to check a motor’s ability to adopt with your
mechanism and applications: Motor life, electric noise, mechanical noise,
vibration, static-electrical noise resistance, power-source noise
resistance, drift of rpm, electrical resonance between control circuit and
motor, mechanical resonance between subassembly and motor malfunction due to
motor noise, electrical magnetic interference, malfunction due to magnetic
flux leakage, destruction due to lightning-related power surge, grounding.
8-5 Some particular plastic materials
can crack and fail after exposure to motor bearing oil. Perform test the
motor in/on the subassembly to check the influence of the oiled plastic
parts.
8-6 Avoid connecting a serial resistor
to the motor if at all possible, as this can negatively affect reliability.
If this is unavoidable, keep resistance as low as possible and test
thoroughly for reliability before using.
8-7 When testing for UL, CSA or other
safely standards, apply for approval for the entire subassembly.
8-8 Do not store motors under conditions
of extreme temperatures or high humidity, or for longer than six months even
room conditions. When removing out of packaging after storage, take
precautions to prevent condensation. 8-9 Connections:
Complete soldering operations within three seconds to prevent damage to
leads and terminals. Make sure that the soldering tip does not exceed 350°C.
Be gentle with terminals; dents or pressure on them can lock up the motor.
8-10 Please consults us in advance when
design considerations call for forcefully stalling the motor using a short
circuit at the terminal or reverse voltage. Such operations can shorten
product life. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Home | Product Info | About us | Factory tour | ISO Certifications | RoHS Info | Sample Request | Contact us |