General
scope
1-1
The specifications apply to the coreless cylindrical permanent magnetic
micro vibration motor DC model Z6SC0A0150081.
2. Operating conditions
3-4 All data are based on the measuring conditions: Temperature, 20°C; Humidity, 65% RH. If any disagreement occurs, such test conditions are available: Temperature, 5~35°C; Humidity, 45 ~ 85% RH. 4. Mechanical specifications
5.
Performance and characteristics
6. Reliability Test
7. Post environmental
8.
Caution and Matters 8-1
Warnings: In a motor near the end its life, or under breakdown
conditions, short circuits can develop between commutator segments.
Uncontrolled voltage may then leak into the power source circuit. Motors may
overheat or fail if run continuously with its rotor locked condition or
under excessive loads. 8-2
Destructive atmospheres: Do not use and store the motor in the corrosive
gas atmosphere (H2S, SO2, NO2, Cl2,
etc.), or substances that can emit toxic gases, such as organic silicon,
cyanide, formalin, or phenol compounds. The motor may get serious damages.
8-3 Condensation: Condensation on the electrical
circuits can destroy the motor or control circuits. Monitor the environment
and undertake measures to prevent condensation, such as installing
condensation sensors to cut power when necessary.
8-4 Be aware of the following factors and
perform necessary tests to check a motor’s ability to adopt with your
mechanism and applications: Motor life, electric noise, mechanical noise,
vibration, static-electrical noise resistance, power-source noise
resistance, drift of rpm, electrical resonance between control circuit and
motor, mechanical resonance between subassembly and motor malfunction due to
motor noise, electrical magnetic interference, malfunction due to magnetic
flux leakage, destruction due to lightning-related power surge, grounding.
8-5 Some particular plastic materials can crack
and fail after exposure to motor bearing oil. Perform test the motor in/on
the subassembly to check the influence of the oiled plastic parts.
8-6 Avoid connecting a serial resistor to the
motor if at all possible, as this can negatively affect reliability. If this
is unavoidable, keep resistance as low as possible and test thoroughly for
reliability before using.
8-7 When testing for UL, CSA or other safely
standards, apply for approval for the entire subassembly.
8-8 Do not store motors under conditions of
extreme temperatures or high humidity, or for longer than six months even
room conditions. When removing out of packaging after storage, take
precautions to prevent condensation. 8-9 Connections:
Complete soldering operations within three seconds to prevent damage to
leads and terminals. Make sure that the soldering tip does not exceed 350°C.
Be gentle with terminals; dents or pressure on them can lock up the motor. 8-10 Please consults us in advance when design considerations call for forcefully stalling the motor using a short circuit at the terminal or reverse voltage. Such operations can shorten product life.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|