VibratorMotor.com

VibratorMotor.com

Home     |     Product Info    |     About us     |     Factory tour     |    ISO Certifications    |    RoHS Info    |    Sample Request    |    Contact us   

 

Part No. Z6DL2B0170001  ( Old Part Number : 6DL-17WB )

           Click to Download PDF Format !

 

1.   General scope

1-1 The specifications apply to the coreless cylindrical permanent magnetic micro vibration motor DC model Z6DL2B0170001.

 

2.   Operating conditions

Items

Specifications

Condition & Remarks

2-1

Rated voltage

3.0V DC

 

2-2

Rated load

Counterweight

As specified in 10. Outline drawing.

2-3

Rotation

C.W/ C.C.W  (clockwise or anticlockwise)

 

2-4

Motor position

All positions

 

2-5

Operating voltage

2.2~3.6V DC

 

2-6

Operating conditions

-30 ~ 70°C,

ordinary humidity : 65±20%RH

No condensation of moisture.

2-7

Storage conditions

-40 ~ 80°C,

ordinary humidity : 65±20%RH

No condensation of moisture.

 

 

3.   Measuring conditions

Items

Specifications

Condition & Remarks

3-1

Temperature

20±2°C

 

3-2

Humidity

(63 ~ 67%) RH

 

3-3

Motor position

Motor shaft horizontal

Lock the motor in a test fixture.

 

The measurement at 20°C & 65%RH is standard. If the judgment is not questionable, recognize measurement at

5°C to 35°C & relative humidity 45% to 85%. Direction of motor is shaft
horizontal.

4.   Mechanical specifications

Items

Specifications

Condition & Remarks

4-1

Configuration

As specified in 10. outline drawing

Outline drawing No: Z6DL2B0170001.

4-2

Appearance

There shall be no evidence of mechanical damage and shall not have inadequate corrosion and so on.

Visual examination (allowable extent
is based on boundary sample)

4-3

Shaft end play

0.1 ~ 0.3mm

 

4-4

Holding strength of vibration weight

49N (5kgf)  Min

 

 

5.    Performance and characteristics

Items

Specifications

Condition & Remarks

5-1

Rated speed

8000±2000rpm

At rated voltage and rated load (vibration weight).

5-2

Rated current

85mA max

5-3

Stall current

125mA max

At rated voltage.

5-4

Starting voltage

1.7V DC max

At rated load (vibration weight) any position of rotor.

5-5

Insulation resistance

1MΩ min

At DC 100V between the lead wires and motor body.

5-6

Terminal resistance

30Ω (±20%)  

At 20°C.

5-7

Mechanical noise

50db (A) max

 

At rated voltage and rated load (Counterweight).
Back ground noise 28dB(A) Max
Measuring instruments: B&k
Weight of jig:700g

 

 

 

 

 

 

 

 

 

 

 

 

 

6.    Reliability Test

Items

Standard test conditions

Condition & Remarks

6-1

Life test

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-1.

Position Volt Load Temp Humi Life
Horizon Rated Weight 20°C 65%

200.000

Cycles

6-2

Low temp exposure

Temperature:    -40±2°C

Time:                96hrs

After 2 hours exposure in ordinary Motors shall be approved as specified in item 7-2.

6-3

High temp exposure

Temperature:    -60±2°C

Time:                96hrs

6-4

Humidity exposure

Temperature:    40±2°C

Humidity:          90 ~ 95% RH

Exposure time:   96hrs

No condensation of moisture

6-5

Vibration

Displacement:   1.5mm (p-p)

Frequency:       10 ~ 55~10Hz

Period:             20 Mins log sweep

                     (10 ~ 55 ~ 10Hz)

Direction:          x, y, z

Time:               Each 2 hours

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Set the motor to the approximately 75g (include the motor) weight of block drop the motor on the concrete floor.

Height:             1.5 meters

Direction:          6 faces

Times:              Twice 2 each

After the test motors shall be approved as specified in item 7-2.

6-7

Heat stock test

 

Test cycle: 20 cycles

 

After the test motors shall be approved as specified in item 7-2.

 

7.   Requirements

Items

Requirements

7-1

Table A

1) Rated speed:               data -30% Initial min

                                    data +60% Initial max

2) Rated current:             data ±30% Initial max

3) Starting voltage:           2.0V DC max

7-2

Table B

1) Rated speed:               data -30% min

2) Rated current:             data ±30% max

3) Starting voltage:          2.0V DC max

8Matters to be paid attention to when using motor

8-1 (Please lay the motors carefully in transportation to avoid any serious damage to the motor body or its electric function because of collision.)

8-2 (Please use and storage motors according to N0.2 item (Operating Conditions) in specification, or else motor characteristics would be affected.)

8-3 (Make arrangement to limit the storage period to 6 months or less. Condensation of atmosphere must be avoided in
motor usage or opening the packaging of the motor.)

8-4 (For proper operation. storage and operating environment must not contain corrosive gases. For example H2S. SO2. NO2. CL2. etc. In addition storage environment must not have materials that emit corrosive gases especially from silicon. cyanic. formalin and phenol group. In the mechanism or the set. existence of corrosive gases may cause no rotation in motor.)

8-5 (Please don't stall the shaft for a long time after powering, and not to touch the weight when motor is rotating.)

8-6 (There should be no sundries (such as grain, fibre, hair, small tape, glue etc.) in the shaft end play.)

 

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us

Copyright 2012  ©  VibratorMotor.com