3-4 All data are based on the measuring conditions:
Temperature, 20°C; Humidity, 65% RH. If any disagreement
occurs, such test conditions are available: Temperature,
5~35°C; Humidity, 45 ~ 85% RH.
|
Items
|
Standard test conditions |
Condition & Remarks |
|
6-1
|
Life
test |

|
After 2
hours exposure in ordinary Motors shall be approved as
specified in item 7-1. |
|
Position |
Voltage |
Load |
Temperature |
Humidity |
Life |
|
Horizontal |
Rated |
Counter
weight |
20 ºC |
65 % |
200,000
cycles |
|
40 ºC |
9 0 % |
40,000
cycles |
|
|
6-2 |
Low
temperature exposure test |
Temperature: -40±2°C
Time: 24hrs |
After
the test motors shall be approved as specified in item
7-2. |
|
6-3 |
High
temperature exposure test |
Temperature: 85±2°C
Time: 300hrs |
|
6-4 |
High
humidity exposure test |
Temperature: 40±2°C
Humidity: 90% RH
Exposure time: 96hrs
Dry time: 4 hrs
No condensation of moisture |
|
6-5
|
Vibration test |
Displacement: 1.5mm (p-p)
Frequency: 10 to 55Hz
Period: 20 Mins log sweep (10 ~ 55 ~
10Hz)
Direction: x, y, z
Time: Every 2 hours |
After
the test motors shall be approved as specified in item
7-2. |
|
6-6
|
Drop
test |
Set the
motor to the approximately 75g (include the motor)
weight of block drop the motor on the concrete floor.
Height: 1.5 meters
Direction: ±x, ±y, ±z
Times: Every 2 hours |
After
the test motors shall be approved as specified in item
7-2. |
|
6-7
|
Heat
stock |
Test cycle: 5 cycles
 |
After
the test motors shall be approved as specified in item
7-2. |