Home | Product Info | About us | Factory tour | ISO Certifications | RoHS Info | Sample Request | Contact us |
|||
1.
General Description
This specification applies to coin-shape permanent-magnetic motor DC model
C1030B028F.
2.
Operating
condition
|
Item |
Specification |
Conditions |
|
2-1 |
Rated voltage |
3.0V DC |
|
2-2 |
Operating voltage |
2.7~3.3V DC |
|
2-3 |
Direction of vibration |
CW (clockwise) or CCW (counter clockwise) |
|
2-4 |
Operating environment |
-20~+60°C, Ordinary Humidity |
|
2-5 |
Storage environment |
-30~+70°C, Ordinary Humidity |
3.
Measuring condition
|
Item |
Specification |
Conditions |
|
3-1 |
Temperature |
25±3°C |
|
3-2 |
Humidity |
65±20% RH |
|
3-3 |
Power supply |
Constant Power supply 3.0V |
4.
Electrical initial characteristics
|
Item |
Specification |
Conditions |
|
|
4-1 |
Rated speed: 9,000 rpm |
At rated voltage |
|
|
4-2 |
Rated current: 100 mA Max |
|
|
|
4-3 |
Starting current: 120 mA Max |
|
|
|
4-4 |
Starting voltage: 2.3V DC Max |
Motor is rotating at min starting
voltage. |
|
|
4-5 |
Insulation resistance 10 MΩ Min
|
At DC 100 V between lead wire and case. |
|
|
4-6 |
Terminal resistance
|
32 Ω ± 15% ( single posture ) 62 Ω ± 15% ( compose posture ) |
25°C at 25°C |
5.
Mechanical characteristics
|
Item |
Specification |
|
|
5-1 |
Bracket Deflection
strength |
9.8N or more |
|
5-2
|
Mechanical
noise |
50dB
(A) Max |
|
At
rated voltage
Back
ground noise 28dB(A) Max
|
||
6.
Reliability characteristics
|
Item |
Specification |
Requirements |
|
|
6-1 |
Lifetime |
Rated voltage: 3.0V DC Test mode: 2s On, 2s Off, as one cycle Test cycle
50,000
cycles
|
After
the test, motors shall be approved as specified in item 7-1. |
|
6-2 |
Low
temperature exposure |
Temperature : -30 Time
: 96 h |
After 4 hours exposure in ordinary
temperature and humidity, motors shall be approved as specified in item
7-2. |
|
6-3 |
High
temperature exposure |
Temperature : +70°C Time
: 96 h |
|
|
6-4 |
Humidity exposure |
Temperature : +40°C Humidity
: 95%RH Exposure time : 96 h
No condensation of moisture |
|
|
6-5 |
Vibration |
Displacement: 1.5mm (p-p) Frequency:
10~55Hz Acceleration:
22m/s2 Period: 10 Minutes log sweep
(10~55~10Hz)
Condition : Samples shall be applied for a period of
10 minutes in 3 axial directions. |
After
the test motors shall be approved as specified in item 7-2. |
|
6-6 |
Free fall |
Set
the motor to a fixture of approx. 100g (include the motor) and
drop it onto the concrete floor. Height
:1.5m Direction
: ±x, ±y, ±z Number of times: Each 3 times |
After
the test motors shall be approved as specified in item 7-2. |
|
6-7 |
Thermal shock |
|
After
4 hours exposure in ordinary temperature and humidity. Motors shall be approved as specified in item 7-2. |
7. Post environment
|
Item |
Specification |
|
|
7-1 |
Table A |
1) Rated speed: No lower than -30% of initial data; No more than +50% initial data. 2) Rated current: No lower than -30% of initial data; No more than +50% initial data. 3) Terminal resistance: No lower than -15% of initial data; No more than +15% initial data. 4) Starting voltage:
2.5V DC Max
5) Insulation resistance :
10 MΩ Min |
|
7-2 |
Table B |
1) Rated speed: No lower than +20% of initial data; No more than -20% initial data. 2) Rated current: No lower than +20% of initial data; No more than -20% initial data. 3) Starting voltage: 2.5V DC Max 4) Terminal resistance: No lower than -15% of initial data; No more than +15% initial data. |
8. Caution for Use
8-1 Unless it is used in accordance with the specifications ,the performance and life may be considerably reduced . Due attention should be paid to voltage and range for use.
8-2 Avoid use or save the motor in the following environment.
- High temperature and high humidity area.
- Corrosive gas such as H2S、SO2、NO2、Cl2.
- Dusty area.
8-3 Due attention must be paid to the handling and working environments because such objects as iron powder if attracted by the motor maganent, will cause noise, characteristic deterioration thus reducing the reliability.
8-4 Please confirm enough no problem of standards and laws and ordinances on your cellular.
8-5 To handle the motor ,hold the motor case softly.
8-6 Rust of plate (steel) and similar edge should be OK.
8-7 Because there is error of the measurement equipment, permit the standard of the rotational frequency to ±5 %.
|
Home | Product Info | About us | Factory tour | ISO Certifications | RoHS Info | Sample Request | Contact us |