1.   General Description
This specification applies to coin-shape permanent-magnetic motor DC model C1030B028F.

 

2.  Operating condition

Item

Specification

Conditions

2-1

Rated voltage

3.0V DC

2-2

Operating voltage

2.7~3.3V DC

2-3

Direction of vibration

CW (clockwise) or CCW (counter clockwise)

2-4

Operating environment

-20~+60°C, Ordinary Humidity

2-5

Storage environment

-30~+70°C, Ordinary Humidity

 

3.  Measuring condition

Item

Specification

Conditions

3-1

Temperature

25±3°C

3-2

Humidity

65±20% RH

3-3

Power supply

Constant Power supply 3.0V DC

 

4.  Electrical initial characteristics

Item

Specification

Conditions

4-1

Rated speed: 9,000 rpm Min

At rated voltage

4-2

Rated current: 100 mA Max

 

4-3

Starting current: 120 mA Max

 

4-4

Starting voltage: 2.3V DC Max

Motor is rotating at min starting voltage.

4-5

Insulation resistance 10 MΩ Min

At  DC 100 V between lead wire and case.

4-6

Terminal resistance

32 Ω ± 15% ( single posture )

62 Ω ± 15% ( compose posture )

    25°C

at 25°C

 

5.  Mechanical characteristics

Item

Specification

5-1

Bracket Deflection strength

9.8N or more

5-2

 

Mechanical noise

50dB (A) Max

At rated voltage

Back ground noise 28dB(A) Max

 

 

 

 

 

6.  Reliability characteristics

Item

Specification

Requirements

6-1

Lifetime

          

Rated voltage: 3.0V DC

Test mode: 2s On, 2s Off, as one cycle

Test cycle 50,000 cycles

After the test, motors shall be approved as specified in item 7-1.

6-2

Low temperature exposure

Temperature : -30°C

Time            : 96 h

After 4 hours exposure in ordinary temperature and humidity, motors shall be approved as specified in item 7-2.

6-3

High temperature exposure

Temperature : +70°C

Time            : 96 h

 

6-4

Humidity exposure

Temperature : +40°C

Humidity       : 95%RH

Exposure time : 96 h   

No condensation of moisture

 

6-5

Vibration

Displacement: 1.5mm (p-p)

Frequency:        10~55Hz

Acceleration:      22m/s2

Period: 10 Minutes log sweep

             (10~55~10Hz)

Condition    : Samples shall be applied for a period of 10 minutes in 3 axial directions.

After the test motors shall be approved as specified in item 7-2.

6-6

Free fall

Set the motor to a fixture of approx. 100g (include the motor) and drop it onto the concrete floor.

Height   :1.5m

Direction  : ±x, ±y, ±z

Number of times: Each 3 times

After the test motors shall be approved as specified in item 7-2.

6-7

Thermal shock

     

Test mode: 1 hour at -40°C, 1 hour at +85°C, as one cycle. Transfer time between extreme temperatures:< 5/5min/Test cycle: 15 cycles

After 4 hours exposure in ordinary temperature and humidity. Motors shall be approved as specified in item 7-2.

 

7.    Post environment

Item

Specification

7-1

Table A

1) Rated speed:         No lower than -30% of initial data;

                               No more than +50% initial data.

2) Rated current:        No lower than -30% of initial data;

                               No more than +50% initial data.

3) Terminal resistance: No lower than -15% of initial data;

                               No more than +15% initial data.

4) Starting voltage:           2.5V DC Max

5) Insulation resistance :    10 MΩ Min

7-2

Table B

1) Rated speed:         No lower than +20% of initial data;

                               No more than -20% initial data.

2) Rated current:        No lower than +20% of initial data;

                               No more than -20% initial data.

3) Starting voltage:           2.5V DC Max

4) Terminal resistance: No lower than -15% of initial data;

                               No more than +15% initial data.

 

8.   Caution for Use

8-1 Unless it is used in accordance with the specifications ,the performance and life may be considerably reduced . Due attention should be paid to voltage and range for use.

8-2 Avoid use or save the motor in the following environment.

- High temperature and high humidity area.

- Corrosive gas such as H2SSO2NO2Cl2.

- Dusty area.

8-3 Due attention must be paid to the handling and working environments because such objects as iron powder if attracted by the motor maganent, will cause noise, characteristic deterioration thus reducing the reliability.

8-4 Please confirm enough no problem of standards and laws and ordinances on your cellular.

8-5 To handle the motor ,hold the motor case softly.

8-6 Rust of plate (steel) and similar edge should be OK.

8-7 Because there is error of the measurement equipment, permit the standard of the rotational frequency to ±5 .

 

Home Product Info | About us  | Factory tour  | ISO Certifications  |  RoHS Info | Sample Request  |  Contact us

Copyright 2010  ©  VibratorMotor.com